We followed the full conversion process for a 1,600 sq ft 1950s bungalow in a cold-climate zone. The house previously ran an oil furnace and hot-water radiators. The homeowner opted for a ducted cold-climate air-source heat pump with a backup electric boiler for domestic hot water. This case study documents the decisions, timeline, costs, and first-winter performance.
Project goals
- Eliminate oil deliveries and on-site fuel storage
- Reduce annual heating carbon footprint by at least 50%
- Maintain or improve comfort levels without major structural alterations
Scope of work
Major steps included:
- Manual J load calculation and mechanical plan
- Replacement of oil furnace with a cold-climate air-source heat pump and upgraded ductwork
- Installation of an electric boiler for domestic hot water (tankless electric) and retention of existing radiators during transition
- Air sealing and insulation upgrades in attic and rim joists
Cost breakdown (approximate)
- Heat pump & indoor unit (3-ton variable speed): $9,800
- New ductwork and registers: $4,200
- Electrical panel upgrade and wiring: $2,500
- Air sealing & insulation improvements: $3,100
- Labor and miscellaneous (permits, commissioning): $3,400
- Total installed cost (pre-rebate): $23,000
Incentives and net cost
After federal and state rebates totaling $7,500, the homeowner’s net cost was approximately $15,500. The contractor also offered a 2-year maintenance package that included two annual tune-ups.
Performance after one winter
Key results:
- Energy bills: The homeowner’s winter heating bill dropped by ~38% compared to the previous year, after accounting for grid electricity price changes.
- Comfort: Even heat distribution improved; the system’s variable speed operation reduced temperature swings.
- Cold performance: The heat pump operated well down to -10°F for most heating loads; on the coldest nights auxiliary electric heat engaged briefly but made up a small portion of overall energy consumption.
Lessons learned
- Start with the envelope: Air sealing and added insulation reduced required capacity and improved comfort.
- Choose an installer with retrofit experience: The contractor’s experience with older homes helped avoid oversizing and address duct challenges.
- Plan electrical upgrades early: Panel upgrades delayed the project by two weeks when not accounted for in the initial quote.
"The conversion delivered both environmental benefits and improved comfort, with payback expected in under 10 years when incentives and reduced oil purchases are considered." — Homeowner testimonial
Final verdict
The conversion succeeded on the homeowner’s goals: eliminating oil, cutting emissions, and improving comfort. Key takeaways for other homeowners: budget for envelope upgrades, verify installer retrofit experience, and secure rebates early. A thorough load calculation and properly sequenced work made the difference.